学科分类
/ 1
7 个结果
  • 作者: Huang Ji-Hui Liao Hui Tan Xin-Yu Xing Wei-Rong Zhou Qi Zheng Yu-Shi Cao Hong-Yu Zeng Can-Jun
  • 学科: 医药卫生 >
  • 创建时间:2020-08-10
  • 出处:《中华医学杂志(英文版)》 2020年第04期
  • 机构:Department of Orthopedics, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong 510630, China; Southern Medical University, Guangzhou, Guangdong 510515, China,Department of Orthopedics, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong 510630, China,Musculoskeletal Disease Center, Jerry L. Pettis Memorial Veterans Affairs Medical Center, Loma Linda, CA 92357, USA;Department of Medicine, Loma Linda University, Loma Linda, CA 92354, USA.,Southern Medical University, Guangzhou, Guangdong 510515, China
  • 简介:AbstractBackground:Surgical treatment of both-column acetabular fractures is challenging because of the complex acetabular fracture patterns and the curved surface of the acetabulum. Seldom study has compared the application of three-dimensional (3D) printing technology and traditional methods of contouring plates intra-operatively for the surgical treatment of both-column acetabular fractures. We presented the use of both 3D printing technology and a virtual simulation in pre-operative planning for both-column acetabular fractures. We hypothesized that 3D printing technology will assist orthopedic surgeons in shortening the surgical time and improving the clinical outcomes.Methods:Forty patients with both-column acetabular fractures were recruited in the randomized prospective case-control study from September 2013 to September 2017 for this prospective study (No. ChiCTR1900028230). We allocated the patients to two groups using block randomization (3D printing group, n = 20; conventional method group, n = 20). For the 3D printing group, 1:1 scaled pelvic models were created using 3D printing, and the plates were pre-contoured according to the pelvic models. The plates for the conventional method group were contoured during the operation without 3D printed pelvic models. The operation time, instrumentation time, time of intra-operative fluoroscopy, blood loss, number of times the approach was performed, blood transfusion, post-operative fracture reduction quality, hip joint function, and complications were recorded and compared between the two groups.Results:The operation and instrumentation times in the 3D printing group were significantly shorter (130.8 ± 29.2 min, t = -7.5, P < 0.001 and 32.1 ± 9.5 min, t = -6.5, P < 0.001, respectively) than those in the conventional method group. The amount of blood loss and blood transfusion in the 3D printing group were significantly lower (500 [400, 800] mL, Mann-Whitney U= 74.5, P < 0.001 and 0 [0,400] mL, Mann-Whitney U = 59.5, P < 0.001, respectively) than those in the conventional method group. The number of the approach performed in the 3D printing group was significantly smaller than that in the conventional method group (pararectus + Kocher-Langenbeck [K-L] approach rate: 35% vs. 85%; x2 = 10.4, P < 0.05). The time of intra-operative fluoroscopy in the 3D printing group was significantly shorter than that in the conventional method group (4.2 ± 1.8 vs. 7.7 ± 2.6 s; t = -5.0, P < 0.001). The post-operative fracture reduction quality in the 3D printing group was significantly better than that in the conventional method group (good reduction rate: 80% vs. 30%; x2 = 10.1, P < 0.05). The hip joint function (based on the Harris score 1 year after the operation) in the 3D printing group was significantly better than that in the conventional method group (excellent/good rate: 75% vs. 30%; x2 = 8.1, P < 0.05). The complication was similar in both groups (5.0% vs. 25%; x2 = 3.1, P = 0.182).Conclusions:The use of a pre-operative virtual simulation and 3D printing technology is a more effective method for treating bothcolumn acetabular fractures. This method can shorten the operation and instrumentation times, reduce blood loss, blood transfusion and the time of intra-operative fluoroscopy, and improve the post-operative fracture reduction quality.Clinical trail registration:No.ChiCTR1900028230; http://www.chictr.org.cn

  • 标签: Both-column Acetabulum fractures Computer simulation Three-dimensional printing Internal fracture fixation
  • 简介:AbstractMandibular condylar fractures are among the most common facial fractures and some of the most difficult to manage. Opinions about the management of mandibular condylar fractures differ among surgeons. With the implementation of new technology, an increased understanding of fracture management, and better functional and morphological outcomes reported in the literature, open reduction and internal fixation is becoming many surgeons’ preferred choice for the treatment of condylar fractures. Because surgical treatment of such fractures is complex, certain factors must be considered to achieve satisfactory outcomes. In this article, we summarise six key points in the management of mandibular condylar fractures: virtual evaluation of condylar fracture, a suitable surgical approach, good reduction, stable internal fixation, repair of the articular disc, and restoration of the mandibular arch width. We believe that these points will help to improve the prognosis of mandibular condyle fractures.

  • 标签: Mandibular fractures Condylar fractures Template
  • 作者: Becker Alexander Yaslowitz Ori Dubose Joseph Peleg Kobi Daskal Yaakov Givon Adi Group Israel Trauma Kessel Boris
  • 学科: 医药卫生 >
  • 创建时间:2020-08-10
  • 出处:《中华创伤杂志(英文版)》 2020年第03期
  • 机构:Department of Surgery, Emek Medical Center, Afula, Israel; The Rappaport School of Medicine, Technion, Haifa, Israel,Department of Surgery A, Meir Medical Center, Kfar-Saba, Israel,R Adams Cowley Shock Trauma Center, University of Maryland Medical System, Baltimore, MD, USA,National Center for Trauma and Emergency Medicine Research, Gertner Institute for Epidemiology and Health Policy Research, Tel Hashomer, Israel; Emergency and Disaster Management Department, Faculty of Medicine, School of Public Health, Tel-Aviv University, Israel,Trauma Unit, Hillel Yaffe Medical Center, Hadera, Israel,National Center for Trauma and Emergency Medicine Research, Gertner Institute for Epidemiology and Health Policy Research, Tel Hashomer, Israel,Emergency and Disaster Management Department, Faculty of Medicine, School of Public Health, Tel-Aviv University, Israel,The Rappaport School of Medicine, Technion, Haifa, Israel; Trauma Unit, Hillel Yaffe Medical Center, Hadera, Israel
  • 简介:AbstractPurpose:Pelvic fracture evaluation with abdominopelvic computed tomography (CT) and formal CT cystography for rule out of urine bladder injury have been commonly employed in pediatric trauma patients. The additional delayed imaging required to obtain optimal CT cystography is, however, associated with increased doses of ionizing radiation to pelvic organs and represent a significant risk in the pediatric population for future carcinogenic risk. We hypothesized that avoidance of routine CT cystography among pediatric pelvic fracture victims would not result in an appreciable rate of missed bladder injuries and would aid in mitigating the radiation exposure risk associated with these additional images.Methods:A retrospective cohort study involving blunt trauma pelvic fractures among pediatric trauma patients (age<14) between the years 1997 and 2016 was conducted utilizing the Israeli National Trauma Registry. Statistical analysis was performed using SAS statistical software version 9.4 via the tests of Chisquare test and two-sided Fisher's exact test. A p value of less than 0.05 was considered statistically significant.Results:A total of 1072 children were identified from the registry for inclusion. Mean age of patients was 7.7 years (range 0-14) and 713 (66.5%) were male. Overall mortality in this population was 4.1% (44/1072). Only 2.1% (23) of pediatric patients with pelvic fractures had bladder injury identified, with just 9 children having intraperitoneal bladder rupture (0.8% of all the patients).Conclusion:The vast majority of blunt pediatric trauma victims with pelvic fractures do not have urine bladder injuries. Based on our study results we do not recommend the routine utilization of CT cystography in this unique population.

  • 标签: Tomography X-ray computed Cystography Bladder injury Child Pelvic fracture
  • 简介:AbstractBackground:The importance of identifying osteoporotic vertebral endplate or/and cortex fracture (ECF), which primarily includes endplate fracture (EPF) and vertebral anterior cortex buckling, has been recognized. However, some old traumatic ECFs with healing process in the elderly may be mistaken as osteoporotic. This study analyzes the radiological features of traumatic EPF.Methods:This was a retrospective analysis of 194 spine trauma patients with 263 vertebral fractures (mean age: 42.11 ± 9.82 years, 118 males and 76 females). All patients had traumatic EPF identified by X-ray/CT/MRI.Results:The involved vertebra was mostly L1 (29.7%), followed by T12 and L2. Except EPFs involved both superior and inferior endplates (12.6%), only 1.9% involved inferior endplate alone, with the majority involved superior endplate. If each endplate was divided into five segments of equal lengths (from anterior to posterior: a1, a2, m, p2, p1), the most depressed point of superior EPFs was mostly at segment-a2 (approximately 45%), followed by segment-a1 (approximately 20%) or segment-m (approximately 20%), and very rarely at segment-p1. The upper 1/3 of anterior vertebral wall was more likely to fracture, followed by middle 1/3 of anterior wall. For posterior vertebral wall fracture, 68.5% broke the bony wall surrounding the basivertebral vain. 58.6%, 30.0%, and 11.4% of vertebral fractures had <1/5, 1/5-1/3, and >1/3 vertebral body height loss. As the extent of vertebral height loss increased, the chance of having both superior and inferior EPFs also increased; however, the chance of having inferior EPF alone did not increase.Conclusion:Traumatic EPF features are characterized, which may help the differentiation of traumatic and osteoporotic EPFs.

  • 标签: Spine Vertebral fracture Endplate Traumatic Vertebral cortex
  • 简介:AbstractBackground:The purpose of this study was to analyze cases of AO31-A2 intertrochanteric fractures (ITFs) and to identify the relationship between the loss of the posteromedial support and implant failure.Methods:Three hundred ninety-four patients who underwent operative treatment for ITF from January 2003 to December 2017 were enrolled. Focusing on posteromedial support, the A2 ITFs were divided into two groups, namely, those with (Group A, n = 153) or without (Group B, n = 241) posteromedial support post-operatively, and the failure rates were compared. Based on the final outcomes (failed or not), we allocated all of the patients into two groups: failed (Group C, n = 66) and normal (Group D, n = 328). We separately analyzed each dataset to identify the factors that exhibited statistically significant differences between the groups. In addition, a logistic regression was conducted to identify whether the loss of posteromedial support of A2 ITFs was an independent risk factor for fixation failure. The basic factors were age, sex, American Society of Anesthesiologists (ASA) score, side of affected limb, fixation method (intramedullary or extramedullary), time from injury to operation, blood loss, operative time and length of stay.Results:The failure rate of group B (58, 24.07%) was significantly higher than that of group A (8, 5.23%) (χ2 = 23.814, P < 0.001). Regarding Groups C and D, the comparisons of the fixation method (P = 0.005), operative time (P = 0.001), blood loss (P = 0.002) and length of stay (P= 0.033) showed that the differences were significant. The logistic regression revealed that the loss of posteromedial support was an independent risk factor for implant failure (OR = 5.986, 95% CI: 2.667–13.432) (P < 0.001).Conclusions:For AO31-A2 ITFs, the loss of posteromedial support was an independent risk factor for fixation failure. Therefore, posteromedial wall reconstruction might be necessary for the effective treatment of A2 fractures that lose posteromedial support.

  • 标签: Intertrochanteric fractures AO 31-A2 Loss of posteromedial support Implant fixations Implant failure
  • 简介:AbstractPurpose:Tibial plateau fracture (TPF) is a devastating injury as it shatters lower articular surface of the largest joint. Apart from bony injury, TPF can lead to great soft tissue envelope compromise which affects the treatment plan and outcome. In the present study, clinical results were assessed in cases of high energy TPFs treated in staged manner.Methods:Twenty-three (20 males and 3 females) patients of high energy communited TPFs (Schatzker type V and VI) were consecutively treated.1 All the patient had compromise of overlying skin conditions. They were all successively scheduled for staged treatment plan which comprised of application of bridging knee external fixator on the first day of admission and definitive internal fixation after skin and soft tissue overlying the fracture were healed. Schatzker type I, II, III and IV were excluded from the study. Primary survey was done and patient who had head injury, chest and abdominal injury, pelvic injury and contralateral limb injury and open fractures were excluded from the study. The patients were also evaluated in terms of wound complications, axial and rotary alignment of limb, fixation failure, articular congruity and range of motion of the knees and post injury employment. Statistical analysis was done using SPSS software.Results:Maximum follow-up period was 13 months. All the fractures were united at final follow-up. Clinical evaluation was done with the Tegner Lysholm knee scoring scale.2 Excellent results were found in 78% cases and good and fair results in 22% cases. There was significant correlation between range of motion and the Tegner Lysholm knee score (p < 0.001, Pearson correlation coefficient = 0.741). The correlation between the score and the radiographical union duration was significant (p = 0.006, Pearson correlation coefficient =-0.554).Conclusion:A staged treatment plan allows healing of soft tissue envelope, with avoidance of dreadful complications such as compartment syndrome and chronic infection. In addition, a staged treatment strategy does not hamper the fracture reduction, bony union and the functional results.

  • 标签: High energy fracture Tibial plateau fractures Staged treatment
  • 简介:AbstractBackground:The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial. The purpose of this study was to compare differences in the efficacy of a novel nail (medial support nail [MSN-II]) and proximal femoral nail anti-rotation (PFNA-II) in the treatment of reverse obliquity inter-trochanteric fractures (Arbeitsgemeinschaft fur Osteosynthesfrogen/Orthopedic Trauma Association [AO/OTA] 31-A3.1) using finite-element analysis.Methods:Modeling software was used to establish a three-dimensional model of MSN-II and PFNA-II and an A3.1 inter-trochanteric fracture model. Abaqus software was used to implement different force loads to compare finite-element biomechanical parameters such as the maximum stress in implant and the displacement of fracture site.Results:The femoral stress, implant stress and fracture site displacement of MSN-II was less than that of PFNA-II. The results indicated that the maximal femoral stress was 581 MPa for PFNA-II and 443 MPa for the MSN-II. The maximum stress values in the PFNA-II and MSN-II models were 291 and 241 MPa, respectively. The maximal displacements of the fracture site were 1.47 and 1.16 mm in the PFNA-II and MSN-II models, respectively.Conclusions:Compared with PFNA-II for inter-trochanteric fracture (AO/OTA 31-A3.1), MSN-II which was designed with a triangular stability structure can provide better biomechanical stability. The MSN-II may be a feasible option for the treatment of reverse obliquity inter-trochanteric fracture.

  • 标签: Finite-element analysis Inter-trochanteric fracture Proximal femoral nail anti-rotation