Centrifuge modeling of PGD response of buried pipe

在线阅读 下载PDF 导出详情
摘要 AnewcentrifugebasedmethodfordeterminingtheresponseofcontinuousburiedpipetoPGDispresented.ThephysicalcharacteristicsoftheRPI's100g-tongeotechnicalcentrifugeandthecurrentlifelineexperimentsplit-boxaredescribed:Thesplit-boxcontainsthemodelpipelineandsurroundingsoilandismanufacturedsuchthathalfcanbeoffset,inflight,simulatingPGD.Inaddition,governingsimilituderelationswhichallowonetodeterminethephysicalcharacteristics,(diameter,wallthicknessandmaterialmodulusofelasticity)ofthemodelpipelinearepresented.Finally,recordedstrainsinducedintwoburiedpipeswithprototypediametersof0.63mand0.95m(24and36inch)subjectto0.6and2.0meters(2and6feet)offullscalefaultoffsetsandpresentedandcomparedtocorrespondingFEresults.
机构地区 不详
出版日期 2005年01月11日(中国期刊网平台首次上网日期,不代表论文的发表时间)