简介:【摘要】目的:分析海南省申报医疗器械注册体系核查、生产许可(含延续、变更)检查,以期提升各医疗器械企业(含注册人、生产企业)质量管理水平,切实履行好企业主体责任,保障产品安全、有效和质量可控。方法:汇总分析海南省2023年168家次医疗器械注册体系核查、生产许可检查时发现的缺陷。结论:通过汇总分析海南省医疗器械注册体系核查、生产许可检查发现的问题,发现企业在机构与人员、文件管理、设计开发等方面的缺陷占比较多,存在一定的风险隐患。因此建议对我省医疗器械企业仍需加强监管,深化风险防控,进一步督促医疗器械企业落实主体责任、强化产品质量管理和风险防范。
简介:AbstractObjective:The aim of this work was to explore the feasibility of in vivo and non-invasive monitoring of deuterium/hydrogen (2H/1H) exchange at the metabolic level upon exposure to heavy water (2H2O).Methods:The healthy female mice were randomly assigned to two groups after day 0 when both mice received standard drinking water. The treated mouse was fed with 2H2O (80%, v/v) and the control mouse fed with standard drinking water (H2O) over next 13 days. Real-time mass spectrometric analysis of volatile metabolism emitted through breathing and the skin was performed on days 1, 2, 3, 10, 12, and 13. Animal experiment was approved by the Laboratory Animal Ethics Committee of Jinan University (approval No. 20161117163322) on October 29, 2021.Results:We observed a replacement of 1H by 2H in 52 mass spectral features (60 2H/1H isotopologue pairs) for the mouse fed with 2H2O, but not for the control mouse. These included pyruvic acid and lactic acid, lysine and methyl-lysine as well as short-chain fatty acids comprising acetic acid, propionic acid, butyric acid and valeric acid.Conclusion:Secondary electrospray ionization-high resolution mass spectrometry allows monitoring in vivo2H-incorporation of metabolites in a non-invasive and real-time setup and opens new opportunities to use 2H tracing to extend current metabolic studies, especially those with a focus on anaerobic glycolysis, lysine methylation and gut microbiome via monitoring of short-chain fatty acids.
简介:无
简介:BackgroundTaxifolin(Tax)isanessentialnaturalantioxidant.MultiplestudieshaveshownthatTaxcanprotectcardiomyocytesfromischemia-reperfusioninjury.However,theunderlyingmechanismisstillunclear.MethodsH9C2cellswererandomlydividedintocontrol,H_2O_2group,Taxpretreatmentgroup(Tax+H_2O_2);Taxeffectgroup.CellactivitywasdetectedbyCCK-8andtheintracellularstructurewasobservedbytransmissionelectronmicroscopy.AutophagywasdeterminebyWesternblottinganalysisofBeclin-1,Bcl-2andPKC.ResultsTaxpretreatmentsignificantlyincreasedanti-apoptoticproteinBcl-2andautophagyproteinBeclin-1.ExpressionofPKCwasinhibitedbyTax.ConclusionsTaxpretreatmentcouldprotectH9C2cellsagainstH_2O_2-induceddamagethroughtheBcl-2andautophagypathways.
简介:摘要目的朗迈2(LabUmat2+Urised2)全自动尿液分析仪是LabUmat2尿液干化学分析仪和Urised2尿液有型成分分析仪通过同一标本运输轨道联机检测尿常规的全自动仪器。检测项目多、速度快、精密度高,尿液有形成分分析结合人工显微镜检查准确度高。方法LabUmat2全自动尿液干化学分析仪反射光度计法,折射仪法。Urised2全自动尿液有型成分分析仪自动离心镜检,影像式神经网络智能识别系统检测。结果LabUmat2分析仪,配用专用的尿液分析试纸条,检测尿液化学成分;Urised2分析仪检测尿液有形成分。结论朗迈2(LabUmat2+UriSed2)全自动尿液分析仪应用全过程严格按照检测前、检测中、检测后的质量保证体系做好全程质量控制,可及时、准确获得尿常规报告,为临床诊断、疗效监测、预后判断提供可靠依据。同时也是临床实验室尿常规检测技术的提高。