学科分类
/ 4
71 个结果
  • 简介:  【摘 要】目的:探讨常规凝血检验项目对异位妊娠大出血输血治疗不良反应监测的价值。方法:选取笔者所在医院的 100例异位妊娠大出血输血患者,根据患者有无输血不良反应分为观察组和对照组,每组 50例,无不良反应的为观察组,有不良反应的为对照组,分析两组患者的凝血功能指标和血常规指標。结果:观察组患者凝血酶时间( 15.31±1.42) s,活化部分凝血活酶时间( 26.43±1.42) s,纤维蛋白原水平( 1.35±1.12) g/L,凝血酶原时间( 11.36±2.67) s,均低于对照组患者,而 PLT、 HCT、 RBC、 Hb水平均高于对照组患者,差异均有统计学意义( P<0.05)。结论:常规凝血检验项目可对异位妊娠大出血输血治疗不良反应有效监测。    【关键词】常规凝血检验项目 ;异位妊娠大出血输血 ;不良反应    [Abstract] Objective: To explore the value of routine blood coagulation test items in monitoring adverse reactions of blood transfusion treatment of ectopic pregnancy hemorrhage. Methods: 100 cases of blood transfusion patients with ectopic pregnancy hemorrhage in our hospital were selected and divided into the observation group and the control group according to whether the patients had adverse reactions, 50 cases in each group, the observation group without adverse reactions, and the control group with adverse reactions. The coagulation function indexes and blood routine indexes of the two groups were analyzed. Results: thrombin time (15.31 ± 1.42) s, activated partial thromboplastin time (26.43 ± 1.42) s, fibrinogen level (1.35 ± 1.12) g / L, prothrombin time (11.36 ± 2.67) s in the observation group were lower than those in the control group, while PLT, HCT, RBC and Hb levels were higher than those in the control group (P < 0.05). Conclusion: routine blood coagulation test can effectively monitor the adverse reactions of blood transfusion in patients with ectopic pregnancy hemorrhage.

  • 标签:
  • 简介:摘要:目的:对本院老年冠心病以及高血压病患进行同步动态心电图、动态血压监测分析应用价值研究。方法:随机抽选我院34名冠心病病患,并在同时间阶段抽选我院34名高血压病患进行研究,抽选时间为2018年6月~2020年4月,按照其患病性质分为X组(冠心病组)与Y组(高血压组),每组均分有34名病患。对68名病患均使用同步动态心电图、动态血压监测方式,将X组与Y组病患监测情况进行比较。结果:比较X组与Y组监测情况的得出,X组(冠心病组)监测过程中出现心肌缺血症状的病患占比为76.47%(26/34),Y组(高血压组)监测过程中出现心肌缺血症状的病患占比为35.29%(12/34)。且X组病患收缩压为(146.97±8.62)mm Hg,其舒张压为(95.04±7.92)mm Hg;Y组病患收缩压为(126.57±7.26)mm Hg,其舒张压为(78.56±6.24)mm Hg,相较X组均更低。结论:同步动态心电图、动态血压监测分析的应用使得医护人员能够及时发现老年冠心病、高血压病患存在的心肌缺血症状,并监测其血压值、心脏功能等情况,提升治疗及时性,保证病患生命安全。

  • 标签: 冠心病 老年病患 同步动态心电图 高血压 动态血压监测分析
  • 简介:[ 摘要 ] 目的 分析和掌握黔西南州急性脑炎和脑膜炎症候群监测的病原谱。方法 对黔西南州某院 2016年 1月 1日 至 2019年 6月 30日 急性脑炎/脑膜炎 300名 患者血液、脑脊液、咽拭子、大便采集500份标本,对其进行细菌、病毒、真菌中的新型隐球菌、恶性疟原虫 检测,同时进行分析。结果 标本分离JEV IgM总阳性份数有 20份,总阳性率为 4%,其中病毒性脑炎、病毒性脑膜炎、病毒性脑膜脑炎、化脓性脑膜炎、结核性脑膜炎以及其他脑炎 JEV IgM阳性率分别为 7.78%、 3.17%、 6.25%、 0.00%、 0.00%、 4.44%。 415份血液及脑脊液标本中, 23份 (5.54%)Sp阳性, 17份 (4.1%)Hi阳性 ,16份 (3.86%)Shl阳性 。结论 黔西南州地区存在一定的急性脑炎/脑膜炎症的病例误诊现象,故应当加强对急性脑炎 /脑膜炎症候群监测以及相应临床指导。

  • 标签: [ ] 黔西南州 急性脑炎 / 脑膜炎症候群 病原谱
  • 简介:【摘要】目的:在传染病疫情信息的检测报告管理中采用 PDCA 循环法,分析其具体的应用效果。 方法:本次研究中,以 2016 年 1 月至 2019 年 12 月为研究时间段,其中 2016 年 1 月至 2017 年 12 月为对照组,该组是未实施任何干预手段于传染病疫情信息检测报告管理, 2018 年 1 月至 2019 年 12 月为研究组,该组实施了 PDCA 循环法于传染病疫情信息检测报告管理中。分别对两组的传染病报告率、报告卡填写的准确率以及漏报、晚报的发生概率进行观察并记录。 结果:各项数据的对比中发现,研究组结果更佳,两者之间 差异显著 (P<0.05)。结论:在传染病疫情信息的检测报告管理中采用 PDCA 循环法十分有效,不仅能够有效的改善当前传染病疫情信息检测报告管理的整体质量,而且还极大程度的减少了晚报以及漏报率 。

  • 标签: PDCA 循环法 传染病 疫情 检测报告
  • 简介:  【摘要】 目的:探讨常规凝血检验项目对异位妊娠大出血输血治疗不良反应监测的价值。方法:选取 2017年 2月 -2019年 12月笔者所在医院的 100例异位妊娠大出血输血患者,根据患者有无输血不良反应分为观察组和对照组,每组 50例,无不良反应的为观察组,有不良反应的为对照组,分析两组患者的凝血功能指标和血常规指標。结果:观察组患者凝血酶时间( 15.31±1.42) s,活化部分凝血活酶时间( 26.43±1.42) s,纤维蛋白原水平( 1.35±1.12) g/L,凝血酶原时间( 11.36±2.67) s,均低于对照组患者,而 PLT、 HCT、 RBC、 Hb水平均高于对照组患者,差异均有统计学意义( P<0.05)。结论:常规凝血检验项目可对异位妊娠大出血输血治疗不良反应有效监测。    【关键词】 常规凝血检验项目; 异位妊娠大出血输血; 不良反应  [Abstract] Objective: To explore the value of routine coagulation test in monitoring the adverse reactions in the treatment of massive hemorrhage of ectopic pregnancy. Methods: from February 2017 to December 2019, 100 patients with massive hemorrhage of ectopic pregnancy in our hospital were divided into observation group and control group according to whether they had adverse reactions of blood transfusion. 50 patients in each group were divided into observation group and control group according to whether they had adverse reactions of blood transfusion. Coagulation function indexes and Blood Routine Indexes of the two groups were analyzed. Results: thrombin time (15.31 ± 1.42) s, activated partial thromboplastin time (26.43 ± 1.42) s, fibrinogen level (1.35 ± 1.12) g / L, prothrombin time (11.36 ± 2.67) s in the observation group were lower than those in the control group, while PLT, HCT, RBC, Hb levels were higher than those in the control group (P < 0.05). Conclusion: the routine coagulation test can effectively monitor the adverse reactions in the treatment of ectopic pregnancy massive hemorrhage with blood transfusion.

  • 标签:
  • 简介:摘要:目的:研究以危重症患者为例,分析在对患者液体管理中应用无创血流动力学监测的实际应用效果与应用价值。方法:在2018年10月至2020年10月期间内从我院接受治疗的危急重症患者中抽选172例患者作为研究观察对象,并以随机分组的方式各自分为86例M组与86例N组,在两组患者液体管理中分别应用两种不同的监测手段,其中M组患者以常规监测手段开展液体管理工作,而N组患者则以无创血流动力学监测手段开展液体管理工作,最后对比M组与N组患者在液体管理中的管理效果,并在分析中总结无创血流动力学监测手段的应用价值。结果:在各项体征指标参数对比中,M组与N组相较于治疗前有着明显的改善,且对比中的差异十分显著,由于各指标P值大小为均小于0.05,故而统计学意义具备成立条件,同时在两组改善结果对比中可以看到,N组患者相较于M组改善效果更为优异,另外在两组并发症率对比中,M组并发症率为29.07%(25/86),N组并发症率为5.81%(5/86),在并发症率对比中差异明显,且P值大小为(P=0.0375),统计学意义具备相应的成立条件。结论:相较于常规液体管理手段,无创血流动力学监测具有较高的监测应用价值,在保护患者重要脏器功能、促进液体管理质量得到有效提升中可体现出十分优异的应用价值。

  • 标签: 危急重症 无创血流动力学 体征参数 改善效果 并发症
  • 简介:摘要:目的 了解哈尔滨铁路管内旅客列车二次供水水质卫生情况,并为改水提供理论依据,加强饮用水卫生管理。 方法 收集并分析哈站、哈西站始发旅客列车 2016-2019年二次供水监测数据。结果 对四年二次供水监测结果进行分析,总体合格率仅为 62.5%,影响水质质量的主要因素为微生物指标和消毒指标。 结论 哈局管内近年来二次供水水质情况不容乐观,急需提高供水质量,并提出建议。

  • 标签: 旅客列车 二次供水 监测分析
  • 简介:【摘要】目的:观察老年患者髋关节置换术中应用脑电监测TCI对丙泊酚用量的影响。方法:选择80例ASAⅡ或Ⅲ级择期全麻下行髋关节置换术的老年患者,随机分为两组,试验组采用脑电监测TCI监测仪闭环靶控输注丙泊酚,对照组依据生命体征调节丙泊酚靶控浓度。记录诱导前5min(T1)、诱导后5min(T2)、术毕即刻(T3)、拔管后5min(T4)的MAP、HR,麻醉时间、手术时间、丙泊酚用量、血管活性药物使用情况及等指标。结果:与对照组相比,试验组丙泊酚的用量明显减少(P<0.05);在T2、T3时对照组MAP明显低于试验组(

  • 标签:
  • 简介:【摘要】目的: 探究评价呼出气一氧化氮 (FeNO)监测在哮喘控制治疗中的评估指导作用。 方法: 随机抽取68例支气管哮喘疾病的患者纳入研究范围,其均于 2018年 12月至 2019年 12月入我院接受诊治,将其纳入实验组研究范围,纳入同期体检的 68例健康人员纳入对照组研究范围,均采用呼出气一氧化氮监测方式开展测定,对测定结果进行分析。 结果: 实验组患者的呼出气一氧化氮水平显著高于对照组,实验组的呼出气一氧化氮阳性率显著高于对照组,差异显著,P< 0.05。经治疗后,实验组的呼出气一氧化 氮水平与对照组不存在较大差异,P> 0.05。 结论: 采用呼出气一氧化氮监测对哮喘疾病进行控制,有利于强化病症评估效果,为临床治疗进行有效指导。

  • 标签: 呼出气一氧化氮 FeNO 监测 哮喘控制 评估指导
  • 简介:【摘要】目的:探究分析颅内压及脑电双频指数联合监测在重型颅脑外伤患者术后的临床应用价值。方法: 2018年 6月 --2019年 6月,本院一共收治重型颅脑外伤手术患者 57例,按照 GCS评分结果将患者分为特重度组( GCS评分为 3-5分, n=17例)、重度组( GCS评分为 6-8分, n=40例),每 8h记录两组患者的颅内压及脑电双频指数监测结果,比较两组患者的颅内压及脑电双频指数。结果:特重度组患者的脑电双频指数小于重度组,特重度组的颅内压值大于重度组( P<0.05)。 重度组患者的21天生存率大于 特重度组(P<0.05)。 结论:重型颅脑外伤患者入院时的GCS评分越低,其脑电双频指数越小,颅内压值越高,生存率越低。临床应联合应用颅内压及脑电双频指数监测患者,评估患者的术后生存率。

  • 标签: 颅内压 脑电双频指数 重型颅脑外伤 GCS评分 生存率
  • 简介:  【摘要】 目的 探究动态心电图监测传导阻滞与窦房结功能不良患者起搏器植入术后的应用价值。方法 100例行 DDD型起搏器植入的患者作为研究对象, 将存在传导阻滞的患者作为传导阻滞组( 50例), 存在窦房结功能不良的患者作为窦房结功能不良组( 50例)。两组患者均采用动态心电图监测。比较两组患者的自身心律失常及心室安全起搏的检出率。结果 窦房结功能不良组患者的频发房性早搏、房性心动过速的检出率分别为 30.00%( 15/50)、 34.00%( 17/50), 均高于传导阻滞组患者的 4.00%( 2/50)、 6.00%( 3/50), 差异具有统计学意义( P<0.05)。窦房结功能不良组患者的室性早搏、阵发性房颤、成对室性早搏、短阵室速、多源性室性早搏检出率分别为 22.00%( 11/50)、 10.00%( 5/50)、 16.00%( 8/50)、 10.00%( 5/50)、 10.00%( 5/50), 与传导阻滞组患者的 24.00%( 12/50)、 8.00%( 4/50)、 14.00%( 7/50)、 8.00%( 4/50)、 10.00%( 5/50)比较, 差异均无统计学意义( P>0.05)。窦房结功能不良组患者心室安全起搏的检出率为 26.00%( 13/50), 高于传导阻滞组患者的 10.00%( 5/50), 差异具有统计学意义( P<0.05)。及时调整心房感知器的灵敏度后心室安全起搏的检出率显著降低。结论 窦房结功能不良和传导阻滞患者治疗过程中植入起搏器, 再充分借助动态心电图来监测自身情况, 可以让患者对自身心律失常有更为准确的了解, 对于心律失常症状的有效防治及保障患者的生命安全具有重要意义, 适宜推广使用。    【关键词】 窦房结功能不良 ;传導阻滞 ;起搏器 ;动态心电图 

  • 标签: